Configuration reference

Everything lives in a single INI file:

/etc/hpc_eff/config.ini

If that file does not exist, hpc-eff falls back to src/hpc_eff/config.ini.example relative to the current working directory, which is how you can run it straight from a git checkout, and also why a run from an unexpected directory can appear to ignore your settings.

The whole file is parsed upfront regardless of mode, so a syntax error anywhere (even in a section your mode does not use) crashes the run. What depends on [MODE] control_mode is which sections' values the active regulator actually reads:

Section co2 mode temperature mode
[SYSTEM] yes yes
[MODE] yes yes
[logging] yes yes
[CO2_API] yes n/a
[aggregation] yes n/a
[frequency_tables] yes n/a
[TEMPERATURE_SOURCE] n/a yes
[CPU_THERMO] n/a yes
[GPU_POWER] n/a yes

[MODE]

The single user-facing switch. Required: an unset or unrecognised value makes the run exit with Config error: [MODE] control_mode must be one of: temperature|co2 rather than silently doing nothing.

[MODE]
control_mode=co2
Value CPU regulator GPU regulator
co2 price/CO₂ rating → max-frequency cap off
temperature hysteresis thermal control NVIDIA power limiting, on

CPU regulation is mutually exclusive by construction: one mode, one CPU regulator.


[SYSTEM]

[SYSTEM]
SCORENAME=SPEC2017
SCORE=3.8
POWERREADINGCMD=ipmitool dcmi power reading
DEBUG=yes
Key Default Meaning
SCORENAME / SCORE unknown / (none) The node's benchmark name and score (e.g. its SPEC CPU2017 result), stamped onto every log row so you can later compare throttling impact against a node's rated performance. Set manually; never read back by the tool itself.
POWERREADINGCMD (empty) Command string (split on whitespace, no shell; no pipes/$()) whose output is parsed for power draw.
DEBUG no yes prints the full evaluation trace to stdout.

POWERREADINGCMD output must contain the four ipmitool dcmi power reading lines; only Instantaneous power reading is stored (as power_w), logged only, never acted on.

DEBUG=yes is safe to leave on; cron discards stdout regardless.


[CO2_API]: carbon intensity backend

[CO2_API]
TYPE=nowtricity

TYPE selects the backend; the other backend's keys are ignored.

TYPE=nowtricity (default)

Key Default
NOWTRICITY_USER_AGENT HPC-Eff-Agent
NOWTRICITY_BASE_URL https://www.nowtricity.com/api
NOWTRICITY_ZONE czech-republic

Two endpoints are called per run: emissions-previous-24h/<zone>/ and current-emissions/<zone>/. So a 10-minute interval means ~288 API calls per node per day: check that against your plan's quota before a cluster-wide rollout.

An API key for the default nowtricity backend is sent as X-Api-Key; get one at nowtricity.com.

TYPE=wattnet

Key Default
WATTNET_URL https://api.wattnet.eu/v1/footprints
WATTNET_ZONE CZ
WATTNET_FOOTPRINT_TYPE carbon
WATTNET_SCOPE operational

The 24-hour window is computed automatically. Wattnet returns 15-minute samples, which are averaged into 24 hourly values; the newest hourly average doubles as the "current" value. If fewer than 24 hourly values come back the call fails and the run falls back to the price rating.


[frequency_tables]: rating → frequency map

[frequency_tables]
amd_epyc=2400,2000,1500
intel_xeon_gold=3000,2900,2800,2700,2600,2200
intel_e5=3000,2800,2700,2600,2400,2300
default=3000,2800,2700,2600,2400,2200

Values are MHz, highest first. The key is chosen by matching /proc/cpuinfo:

Key Matches when the model name contains
amd_epyc EPYC
intel_e5 E5- and V3
intel_xeon_gold GOLD
default everything else

Selection is index = round((rating - 1) / 9 × (len - 1)) over the descending-sorted list: rating 1 takes the first entry, rating 10 the last, the rest are spread evenly. The list length is your granularity; see deployment.md.

If the section or the key is missing entirely the built-in fallback 3000,2800,2700,2600,2400,2200 applies, which may be nonsense on your CPU. Set default explicitly.


[aggregation]: combining price and CO₂

[aggregation]
rating_type=average
weight_price=0.6
weight_co2=0.4
Key Default Meaning
rating_type price price | average | max: see regulation-modes.md
weight_price 0.6 Used by average only, normalised against weight_co2
weight_co2 0.4 Used by average only

An unknown rating_type logs a warning and falls back to the price rating.

Fallback chain when a signal is missing: CO₂ unavailable → price rating; price unavailable → CO₂ rating; both unavailable → neutral 5. The node keeps regulating rather than freezing at its last cap.

Rationale for the default weights: regulation-modes.md.


[logging]

[logging]
db_path=/var/lib/hpc_eff/history.db
state_json_path=/var/lib/hpc_eff/state.json
history_length=1000
log_level=INFO
Key Default Meaning
db_path history.db SQLite file. Parent directory is created if needed; WAL mode is enabled.
state_json_path /var/lib/hpc_eff/state.json JSON state file, rewritten each run, chmod 644.
history_length 10 How many past entries state.json keeps.
log_level INFO Python level for the hpc_eff logger (stderr).

history_length only bounds the JSON file, not the database; see monitoring.md for growth/pruning.

log_level affects stderr only, which cron discards.


[TEMPERATURE_SOURCE]: pluggable temperature reading

Used only in temperature mode. The CPU thermal regulator and the GPU power regulator each call this independently, once per run; they don't share a single reading, though for a stable source both calls return the same value in practice.

[TEMPERATURE_SOURCE]
TYPE=ipmi
IPMI_SENSOR_NAME=INLET_AIR_TEMP
TYPE Keys Behaviour
ipmi IPMI_SENSOR_NAME Runs ipmitool sensor reading "<name>" and takes the first number in the output.
http_api HTTP_URL, HTTP_JSON_PATH (optional) GETs the URL (5 s timeout). Tries a bare number, then JSON, then any number in the body.
custom MODULE, FUNCTION (default read) Loads your code and calls it.

HTTP example, for {"temperature": {"value": 25.5}}:

TYPE=http_api
HTTP_URL=http://192.168.1.100/api/greendigit/data
HTTP_JSON_PATH=temperature.value

Without HTTP_JSON_PATH the reader tries the top-level keys temperature, temp, value, data before falling back to a regex for the first number in the response.

Custom reader: MODULE is a path to a .py file or an importable dotted module name; FUNCTION (default read) must return Celsius as a number, or None:

TYPE=custom
MODULE=/opt/mysensors/my_reader.py
FUNCTION=read

Every source swallows its own exceptions and returns None on failure, which makes the whole thermal regulation a no-op for that cycle. A typo in a sensor name therefore looks like "nothing happens", not like an error; check with ipmitool sensor reading "<name>" by hand.


[CPU_THERMO]: thermal CPU control

[CPU_THERMO]
MID_LIMIT=29
HIGH_LIMIT=32
HIGH_FREQUENCY=3.10GHz
MID_FREQUENCY=2.30GHz
LOW_FREQUENCY=1.50GHz
#SLACK_URL=
Key Meaning
MID_LIMIT / HIGH_LIMIT Band edges in °C
HIGH_/MID_/LOW_FREQUENCY Target max frequency per band. Accepts 3.10GHz, 2300MHz, 2300000KHz, or a bare number (MHz below 10000, else kHz).
SLACK_URL Optional incoming webhook, posted to only when the frequency actually changes.

The example limits (29/32 °C) are calibrated for the example sensor shipped alongside them, not a recommendation for any other sensor; see deployment.md for why that matters and how to pick your own.

If any of the five keys is missing the regulator logs a debug line and skips, silently, as far as cron is concerned.

Band logic and hysteresis: regulation-modes.md.


[GPU_POWER]: NVIDIA power limiting

Active in temperature mode only, and a no-op on nodes without NVIDIA GPUs.

[GPU_POWER]
MID_LIMIT=70
HIGH_LIMIT=80
HIGH_POWER=100%
MID_POWER=70%
LOW_POWER=40%
# SLACK_URL=
Key Default Meaning
MID_LIMIT 70 °C, start reducing power above this
HIGH_LIMIT 80 °C, aggressive reduction above this
HIGH_/MID_/LOW_POWER 100% / 70% / 40% Absolute watts (250) or a percentage of the GPU's max limit (70%)

Percentages resolve against nvidia-smi --query-gpu=power.max_limit read from the first GPU only (the code assumes all GPUs in the node are the same model), falling back to that GPU's current limit, and finally to 300 W. All GPUs then get the same absolute limit, derived from the one ambient temperature: this is not per-GPU regulation, and it does not read GPU die temperature.

The temperature comes from [TEMPERATURE_SOURCE], the same reading the CPU thermal regulator uses. The two sections' defaults are on visibly different scales ([CPU_THERMO] at 29/32 °C, [GPU_POWER] at 70/80 °C), so they cannot both be right for one sensor. Depending on the range your sensor actually produces, one section's thresholds may never trigger while the other's fire constantly. Set both pairs against that range.


Next

regulation-modes.md: what each mode does with these keys, the rating maths, the thermal bands.